{"product_id":"resmed-airsense-10-autoset-with-humidair-and-climatelineair-37208","title":"ResMed AirSense™ 10 AutoSet™ with HumidAir™ and ClimateLineAir™","description":"\u003cdiv class=\"usa-rx-block\" style=\"border:2px solid #092c55;border-radius:10px;padding:14px 16px;margin:0 0 18px;background:#f5f8fc;\"\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003ePrescription required.\u003c\/strong\u003e This equipment requires a valid prescription from a licensed healthcare provider. It will not ship until US CPAP receives and approves your prescription.\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e\u003ca href=\"\/pages\/submit-prescription\" style=\"display:inline-block;background:#bd0630;color:#ffffff;padding:8px 14px;border-radius:6px;text-decoration:none;font-weight:bold;margin:4px 8px 4px 0;\"\u003eSubmit Your Prescription\u003c\/a\u003e\u003ca href=\"\/pages\/prescription-policy\" style=\"display:inline-block;color:#092c55;font-weight:bold;margin:4px 0;\"\u003ePrescription Verification Policy\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eWe ship this item only within the 50 U.S. states, with a valid U.S. prescription. We do not ship to other territories or countries.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ResMed AirSense 10 AutoSet is ResMed's premium auto-adjusting pressure device, with an integrated HumidAir humidifier. This listing is the AutoSet configuration with HumidAir humidification and ClimateLineAir heated tubing.\u003c\/p\u003e\n\u003cp\u003eThe AirSense 10 AutoSet is indicated for the treatment of obstructive sleep apnea (OSA) in patients weighing more than 66 lb (30 kg). It is intended for home and hospital use. The humidifier is intended for single-patient use in the home environment and reuse in a hospital or institutional environment. In the United States, federal law restricts this device to sale by or on the order of a physician.\u003c\/p\u003e\n\u003cp\u003eThe operating pressure range in AutoSet, AutoSet for Her, Elite, and CPAP modes is 4 to 20 cm H2O. Ramp Time can be set to Off, 5 to 45 minutes, or Auto. When Ramp Time is set to Auto, the device detects when you have fallen asleep and then rises to the prescribed treatment pressure.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated HumidAir humidifier with Humidity Level settings from Off through 1 to 8.\u003c\/li\u003e\n\u003cli\u003eClimateLineAir heated tubing used with Climate Control for more comfortable therapy, as described in the user guide.\u003c\/li\u003e\n\u003cli\u003ePressure Relief, when enabled, can make it easier to breathe out.\u003c\/li\u003e\n\u003cli\u003eSmartStart, when enabled, starts therapy automatically when you breathe into the mask.\u003c\/li\u003e\n\u003cli\u003eMask Fit helps you assess and identify possible air leaks around the mask.\u003c\/li\u003e\n\u003cli\u003eThe device meets Federal Aviation Administration (FAA) requirements (RTCA\/DO-160, section 21, category M) for all phases of air travel. The water tub must be completely empty and inserted for use on a plane, and Airplane Mode should be turned on. Do not use the device with water in the tub on a plane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eAccessories listed in the AirSense 10 user guide include ClimateLineAir, SlimLine, ClimateLineAir Oxy, and Standard air tubing; a standard or cleanable water tub; a side cover for use without the humidifier; standard and hypoallergenic filters; an Air10 DC\/DC converter; an SD card reader; an Air10 oximeter adapter; an Air10 USB adapter; Power Station II; and an Air10 tubing elbow.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eResMed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eAirSense 10 AutoSet with HumidAir and ClimateLineAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003ctd\u003e37208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTherapy modes\u003c\/th\u003e\n\u003ctd\u003eAutoSet, AutoSet for Her, and CPAP (Elite and standard CPAP modes are also documented for the AirSense 10 platform)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure range\u003c\/th\u003e\n\u003ctd\u003e4 to 20 cm H2O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSound pressure level (CPAP mode, ISO 80601-2-70:2015)\u003c\/th\u003e\n\u003ctd\u003e25 dBA ± 2 dBA with SlimLine or Standard tubing; 27 dBA ± 2 dBA with SlimLine or Standard tubing and humidification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSound power level (same conditions)\u003c\/th\u003e\n\u003ctd\u003e33 dBA ± 2 dBA with SlimLine or Standard tubing; 35 dBA ± 2 dBA with SlimLine or Standard tubing and humidification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (H × W × D), device and water tub\u003c\/th\u003e\n\u003ctd\u003e4.57\" × 10.04\" × 5.91\" (116 mm × 255 mm × 150 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight, device and standard or cleanable water tub\u003c\/th\u003e\n\u003ctd\u003e44 oz (1,248 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAir outlet\u003c\/th\u003e\n\u003ctd\u003e22 mm, complies with ISO 5356-1:2004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWater capacity\u003c\/th\u003e\n\u003ctd\u003e380 mL, to the maximum fill line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e90W power supply unit. AC input 100–240 V, 50–60 Hz, 1.0–1.5 A, Class II; 115 V, 400 Hz, 1.5 A, Class II (nominal for aircraft use). DC output 24 V, 3.75 A. Typical consumption 53 W (57 VA); peak 104 W (108 VA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating environment\u003c\/th\u003e\n\u003ctd\u003e41°F to 95°F (5°C to 35°C); 10 to 95% relative humidity, non-condensing; sea level to 8,500 ft (2,591 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage and transport\u003c\/th\u003e\n\u003ctd\u003e−4°F to 140°F (−20°C to 60°C); 5 to 95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003ctd\u003eIEC 60601-1:2005+A1:2012 Class II (double insulation), Type BF, ingress protection IP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAircraft use\u003c\/th\u003e\n\u003ctd\u003eMeets FAA requirements (RTCA\/DO-160, section 21, category M) for all phases of air travel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupplemental oxygen\u003c\/th\u003e\n\u003ctd\u003eMaximum flow 4 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign life (user guide)\u003c\/th\u003e\n\u003ctd\u003eDevice and power supply unit, 5 years; cleanable water tub, 2.5 years; standard water tub and air tubing, 6 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrescription required\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAirSense 10 AutoSet device with integrated HumidAir humidifier\u003c\/li\u003e\n\u003cli\u003eWater tub\u003c\/li\u003e\n\u003cli\u003eClimateLineAir heated tubing, as named in this listing\u003c\/li\u003e\n\u003cli\u003ePower supply unit\u003c\/li\u003e\n\u003cli\u003eTravel bag\u003c\/li\u003e\n\u003cli\u003eSD card (the user guide notes that an SD card is not available in all devices)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eResMed's current U.S. limited warranty, updated March 11, 2025, covers CPAP and bilevel devices, including the external power supply unit, for two years from the date of purchase. It is available only to the initial consumer and is not transferable. Standard humidifier water tubs, ClimateLineAir tubes, SlimLine tubes, and standard tubes are covered for 90 days. Cleanable humidifier water tubs are covered for one year. The limited warranty does not cover damage from improper use, unauthorized repairs, smoke, ozone or other gases, or insect infestation. Warranty claims are made at the point of purchase. For the full terms, see ResMed's warranty information at \u003ca href=\"https:\/\/www.resmed.com\/en-us\/products\/support\/warranty\/\"\u003eresmed.com\/en-us\/products\/support\/warranty\/\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eSee this ResMed therapy device at US CPAP, 1779 Riverdale Street, West Springfield, Massachusetts. Visit the showroom or contact us if you want help matching the exact model on your prescription.\u003c\/p\u003e","brand":"ResMed","offers":[{"title":"Default Title","offer_id":43105482211465,"sku":"37208","price":864.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0658\/3019\/1241\/files\/v0xx6lzd5pqra6jxv9vf.jpg?v=1795364274","url":"https:\/\/uscpap.com\/products\/resmed-airsense-10-autoset-with-humidair-and-climatelineair-37208","provider":"USA Medical Supply","version":"1.0","type":"link"}