ResMed
ResMed AirSense™ 11 AutoSet™ with HumidAir™ and ClimateLineAir™ Auto CPAP Machine
Prescription required. This item ships only after we receive and approve a valid prescription from a licensed healthcare provider. Submit your prescription · Prescription policy
Prescription required. This equipment requires a valid prescription from a licensed healthcare provider. It will not ship until US CPAP receives and approves your prescription.
Prescription required. This equipment requires a valid prescription from a licensed healthcare provider. It will not ship until US CPAP receives and approves your prescription.
We ship this item only within the 50 U.S. states, with a valid U.S. prescription. We do not ship to other territories or countries.
The ResMed AirSense 11 AutoSet is ResMed's premium auto-adjusting pressure device, with an integrated HumidAir 11 humidifier. This listing is the AutoSet configuration with HumidAir humidification and ClimateLineAir 11 heated tubing.
The AirSense 11 self-adjusting system is indicated for the treatment of obstructive sleep apnea (OSA) in patients weighing more than 66 lb (30 kg), including female patients with mild to moderate OSA in AutoSet for Her mode. It is intended for home and hospital use. In the United States, federal law restricts this device to sale by or on the order of a physician.
In AutoSet mode, the device provides only the pressure required to maintain upper airway patency. It analyzes the airway on a breath-by-breath basis and adjusts treatment pressure in response to inspiratory flow limitation, snore, and apnea. AutoSet for Her is also available on this model. The operating pressure range in AutoSet, AutoSet for Her, and CPAP modes is 4 to 20 cm H2O (4 to 20 hPa).
Key Features
- Touch-screen display with a Start Therapy / Standby button, plus a light sensor that adjusts screen brightness to the room.
- Ramp Time can be set to Off, 5 to 45 minutes in 5-minute increments, or Auto.
- Expiratory Pressure Relief (EPR), when enabled by a care provider, reduces pressure during expiration by 1, 2, or 3 cm H2O and will not drop below 4 cm H2O.
- SmartStart and SmartStop, when enabled by a care provider, start therapy when you breathe into the mask and stop it a few seconds after the mask is removed.
- Mask Fit helps you assess and identify possible air leaks around the mask.
- Climate Control is available when both the ClimateLineAir 11 tube and a HumidAir 11 tub are attached. In Auto, the recommended default, tube temperature is set to Auto (80°F / 27°C) and humidifier output is adjusted to maintain 85% relative humidity. Tube temperature can be set from 60 to 86°F (16 to 30°C) or turned off. Humidity Level can be set to Off or 1 through 8.
- The myAir smartphone app can guide setup, including device and mask-fitting videos, Test Drive, and sleep-progress tracking. The app is not required to operate the device and pairs over Bluetooth.
- Over-the-air software updates can download when the device is connected to the cloud, as described in the user guide.
- The device meets Federal Aviation Administration (FAA) requirements (RTCA/DO-160, section 21, category M; RTCA-DO-160, section 20, category T) for all phases of air travel. The humidifier tub must be empty and inserted for use on a plane, and Airplane Mode should be turned on when required. Do not use the device with water in the tub while in transit.
Compatibility
The AirSense 11 is compatible with ResMed masks. For the complete list, see the Mask/Device compatibility list on ResMed.com/downloads/devices. The HumidAir 11 Standard tub and HumidAir 11 Cleanable tub are the only water tubs used with the device. ClimateLineAir 11 is the only heated tubing compatible with AirSense 11. A side cover is available if you want to run the device without the humidifier tub.
Specifications
| Manufacturer | ResMed |
|---|---|
| Model | AirSense 11 AutoSet with HumidAir 11 and ClimateLineAir 11 |
| SKU | 39001 |
| Therapy modes | AutoSet, AutoSet for Her, and CPAP |
| Operating pressure range | 4 to 20 cm H2O (4 to 20 hPa) |
| Sound pressure level (CPAP mode, ISO 80601-2-70:2015) | 27 dBA ± 2 dBA with SlimLine tubing and a half-filled HumidAir 11 tub; 25 dBA ± 2 dBA with SlimLine tubing and the side cover |
| Sound power level (same conditions) | 35 dBA ± 2 dBA with SlimLine tubing and a half-filled HumidAir 11 tub; 33 dBA ± 2 dBA with SlimLine tubing and the side cover |
| Dimensions (H × W × D) with HumidAir 11 tub | 3.72" × 10.21" × 5.45" (94.5 mm × 259.4 mm × 138.5 mm) |
| Dimensions (H × W × D) with side cover | 3.72" × 9.32" × 5.45" (94.5 mm × 236.8 mm × 138.5 mm) |
| Weight, device and HumidAir 11 tub | 40 oz (1,130 g) |
| Weight, device with side cover | 41 oz (1,142 g) |
| Air outlet | 22 mm conical connector, complies with EN ISO 5356-1:2015 |
| Water capacity | 380 mL; time between refills greater than 8 hours ± 0.5 hours, tested at 73.4 ± 3.6°F (23 ± 2°C) |
| Recommended water | Distilled water in the standard tub; drinking-quality (potable) water in the cleanable tub |
| Power supply | Air11 65W AC adaptor. AC input 100–240 V, 50–60 Hz, 2.0 A; 115 V, 400 Hz, 1.5 A for aircraft use. DC output 24 V, 2.71 A. Typical consumption 56.1 W (111.5 VA); peak 73.2 W (137.6 VA) |
| Operating environment | 41°F to 95°F (5°C to 35°C); 10 to 95% relative humidity, non-condensing; sea level to 9,870 ft (3,010 m) |
| Storage and transport | −13°F to 158°F (−25°C to 70°C); 5 to 95% relative humidity, non-condensing |
| Classification | IEC 60601-1 Class II (double insulation), Type BF, ingress protection IP22 |
| Aircraft use | Meets FAA requirements (RTCA/DO-160, section 21, category M; RTCA-DO-160, section 20, category T) for all phases of air travel |
| Supplemental oxygen | Maximum flow 15 L/min |
| Design life (user guide) | Device and power supply unit, 5 years; standard humidifier tub, 6 months; cleanable humidifier tub, 2.5 years; air tubing, 6 months |
| Prescription required | Yes |
What's in the Box
- AirSense 11 AutoSet device
- HumidAir 11 water tub (the user guide lists both the standard tub and the cleanable tub as system water tubs)
- ClimateLineAir 11 heated tubing, as named in this listing
- Air11 65W AC power supply
- Travel bag
- SD card (the user guide notes that an SD card is not available in all devices)
Warranty
ResMed's current U.S. limited warranty, updated March 11, 2025, covers CPAP and bilevel devices, including the external power supply unit, for two years from the date of purchase. It is available only to the initial consumer and is not transferable. Standard humidifier water tubs, ClimateLineAir tubes, SlimLine tubes, and standard tubes are covered for 90 days. Cleanable humidifier water tubs are covered for one year. The limited warranty does not cover damage from improper use, unauthorized repairs, smoke, ozone or other gases, or insect infestation. Warranty claims are made at the point of purchase. For the full terms, see ResMed's warranty information at resmed.com/en-us/products/support/warranty/.
See this ResMed therapy device at US CPAP, 1779 Riverdale Street, West Springfield, Massachusetts. Visit the showroom or contact us if you want help matching the exact model on your prescription.