ResMed
ResMed AirSense™ 10 AutoSet™ with HumidAir™ and ClimateLineAir™
Prescription required. This item ships only after we receive and approve a valid prescription from a licensed healthcare provider. Submit your prescription · Prescription policy
Prescription required. This equipment requires a valid prescription from a licensed healthcare provider. It will not ship until US CPAP receives and approves your prescription.
Prescription required. This equipment requires a valid prescription from a licensed healthcare provider. It will not ship until US CPAP receives and approves your prescription.
We ship this item only within the 50 U.S. states, with a valid U.S. prescription. We do not ship to other territories or countries.
The ResMed AirSense 10 AutoSet is ResMed's premium auto-adjusting pressure device, with an integrated HumidAir humidifier. This listing is the AutoSet configuration with HumidAir humidification and ClimateLineAir heated tubing.
The AirSense 10 AutoSet is indicated for the treatment of obstructive sleep apnea (OSA) in patients weighing more than 66 lb (30 kg). It is intended for home and hospital use. The humidifier is intended for single-patient use in the home environment and reuse in a hospital or institutional environment. In the United States, federal law restricts this device to sale by or on the order of a physician.
The operating pressure range in AutoSet, AutoSet for Her, Elite, and CPAP modes is 4 to 20 cm H2O. Ramp Time can be set to Off, 5 to 45 minutes, or Auto. When Ramp Time is set to Auto, the device detects when you have fallen asleep and then rises to the prescribed treatment pressure.
Key Features
- Integrated HumidAir humidifier with Humidity Level settings from Off through 1 to 8.
- ClimateLineAir heated tubing used with Climate Control for more comfortable therapy, as described in the user guide.
- Pressure Relief, when enabled, can make it easier to breathe out.
- SmartStart, when enabled, starts therapy automatically when you breathe into the mask.
- Mask Fit helps you assess and identify possible air leaks around the mask.
- The device meets Federal Aviation Administration (FAA) requirements (RTCA/DO-160, section 21, category M) for all phases of air travel. The water tub must be completely empty and inserted for use on a plane, and Airplane Mode should be turned on. Do not use the device with water in the tub on a plane.
Compatibility
Accessories listed in the AirSense 10 user guide include ClimateLineAir, SlimLine, ClimateLineAir Oxy, and Standard air tubing; a standard or cleanable water tub; a side cover for use without the humidifier; standard and hypoallergenic filters; an Air10 DC/DC converter; an SD card reader; an Air10 oximeter adapter; an Air10 USB adapter; Power Station II; and an Air10 tubing elbow.
Specifications
| Manufacturer | ResMed |
|---|---|
| Model | AirSense 10 AutoSet with HumidAir and ClimateLineAir |
| SKU | 37208 |
| Therapy modes | AutoSet, AutoSet for Her, and CPAP (Elite and standard CPAP modes are also documented for the AirSense 10 platform) |
| Operating pressure range | 4 to 20 cm H2O |
| Sound pressure level (CPAP mode, ISO 80601-2-70:2015) | 25 dBA ± 2 dBA with SlimLine or Standard tubing; 27 dBA ± 2 dBA with SlimLine or Standard tubing and humidification |
| Sound power level (same conditions) | 33 dBA ± 2 dBA with SlimLine or Standard tubing; 35 dBA ± 2 dBA with SlimLine or Standard tubing and humidification |
| Dimensions (H × W × D), device and water tub | 4.57" × 10.04" × 5.91" (116 mm × 255 mm × 150 mm) |
| Weight, device and standard or cleanable water tub | 44 oz (1,248 g) |
| Air outlet | 22 mm, complies with ISO 5356-1:2004 |
| Water capacity | 380 mL, to the maximum fill line |
| Power supply | 90W power supply unit. AC input 100–240 V, 50–60 Hz, 1.0–1.5 A, Class II; 115 V, 400 Hz, 1.5 A, Class II (nominal for aircraft use). DC output 24 V, 3.75 A. Typical consumption 53 W (57 VA); peak 104 W (108 VA) |
| Operating environment | 41°F to 95°F (5°C to 35°C); 10 to 95% relative humidity, non-condensing; sea level to 8,500 ft (2,591 m) |
| Storage and transport | −4°F to 140°F (−20°C to 60°C); 5 to 95% relative humidity, non-condensing |
| Classification | IEC 60601-1:2005+A1:2012 Class II (double insulation), Type BF, ingress protection IP22 |
| Aircraft use | Meets FAA requirements (RTCA/DO-160, section 21, category M) for all phases of air travel |
| Supplemental oxygen | Maximum flow 4 L/min |
| Design life (user guide) | Device and power supply unit, 5 years; cleanable water tub, 2.5 years; standard water tub and air tubing, 6 months |
| Prescription required | Yes |
What's in the Box
- AirSense 10 AutoSet device with integrated HumidAir humidifier
- Water tub
- ClimateLineAir heated tubing, as named in this listing
- Power supply unit
- Travel bag
- SD card (the user guide notes that an SD card is not available in all devices)
Warranty
ResMed's current U.S. limited warranty, updated March 11, 2025, covers CPAP and bilevel devices, including the external power supply unit, for two years from the date of purchase. It is available only to the initial consumer and is not transferable. Standard humidifier water tubs, ClimateLineAir tubes, SlimLine tubes, and standard tubes are covered for 90 days. Cleanable humidifier water tubs are covered for one year. The limited warranty does not cover damage from improper use, unauthorized repairs, smoke, ozone or other gases, or insect infestation. Warranty claims are made at the point of purchase. For the full terms, see ResMed's warranty information at resmed.com/en-us/products/support/warranty/.
See this ResMed therapy device at US CPAP, 1779 Riverdale Street, West Springfield, Massachusetts. Visit the showroom or contact us if you want help matching the exact model on your prescription.